Module containing the GasBoilerController class.
"""
import numpy as np
from pandaprosumer.mapping.fluid_mix import FluidMixMapping
from pandaprosumer.constants import CELSIUS_TO_K
from pandaprosumer.controller.base import BasicProsumerController
def _calculate_gas_boiler_temp(mdot_kg_per_s, t_out_c, t_in_c, cp_fluid_kj_per_kgk, heating_value_kj_per_kg,
efficiency_percent, max_q_kw, min_q_kw, q_previous_kw, delta_t_previous_c,
max_ramp_up_kw_per_s, max_ramp_down_kw_per_s, time_step_s, allow_stop, max_t_out_c=None):
# FixMe: q_fluid_kw reaches zero only if the max_ramp_down allows it
# FixMe: It doesn't prevent fast turn on / turn off of the boiler
# Calculate the demand heating power
q_fluid_kw = mdot_kg_per_s * cp_fluid_kj_per_kgk * (t_out_c - t_in_c)
# Handle case where input temperature exceeds maximum output temperature
if max_t_out_c is not None and t_in_c > max_t_out_c + 1e-3:
# When t_in_c > max_t_out_c, set t_out_c = t_in_c but mdot = 0 and q_kw = 0
t_out_c = t_in_c
mdot_kg_per_s = 0
q_fluid_kw = 0
# Apply maximum temperature constraint by keeping power constant and adjusting mass flow
elif max_t_out_c is not None and t_out_c > max_t_out_c:
t_out_c = max_t_out_c
# Keep power constant and recalculate mass flow
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
else:
# If temperature difference is too small, set mass flow to zero
mdot_kg_per_s = 0
q_fluid_kw = 0
# If allow_stop is False and power would drop below min_q_kw due to temperature constraint,
# increase mass flow to maintain minimum power
if (min_q_kw is not None and allow_stop == False and
q_fluid_kw > 1e-3 and q_fluid_kw < min_q_kw - 1e-3):
q_fluid_kw = min_q_kw
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Recalculate mass flow to achieve min power at constrained temperature
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
# Apply ramp up/down constraints
if not np.isnan(q_previous_kw): # Constraint not applicable for the first timestep
delta_q = (q_fluid_kw - q_previous_kw)
if max_ramp_up_kw_per_s is not None and delta_q > max_ramp_up_kw_per_s * time_step_s:
# Limit ramp up speed
q_fluid_kw = q_previous_kw + max_ramp_up_kw_per_s * time_step_s
# Recalculate the affected outputs
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
if max_ramp_down_kw_per_s is not None and delta_q < -1 * max_ramp_down_kw_per_s * time_step_s:
# Limit ramp down speed
q_fluid_kw = q_previous_kw - max_ramp_down_kw_per_s * time_step_s
# Recalculate the affected outputs
# Recalculate the fluid mass flow is the temperature difference is > 0
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
elif mdot_kg_per_s > 1e-3:
# If not, recalculate the output temperature instead
t_out_c = t_in_c + q_fluid_kw / (mdot_kg_per_s * cp_fluid_kj_per_kgk)
elif not np.isnan(delta_t_previous_c):
# If the mass flow is also null, recalculate it considering the same temperature difference as the previous timestep
t_out_c = t_in_c + delta_t_previous_c
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
else:
mdot_kg_per_s = 0
q_fluid_kw = 0
t_out_c = t_in_c
# Calculate the necessary amount of fuel from heat value
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Check parameters
if max_q_kw is not None and q_fluid_kw > max_q_kw + 1e-3:
# If the thermal power is too high, recalculate the output mass flow rate
q_fluid_kw = max_q_kw
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# FixMe: Should update the output temperature or the mass flow rate ?
# t_out_c = t_in_c + q_fluid_kw / (mdot_kg_per_s * cp_fluid_kj_per_kgk)
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
# Apply maximum temperature constraint after all other calculations by keeping power constant
if max_t_out_c is not None and t_in_c > max_t_out_c + 1e-3:
# When t_in_c > max_t_out_c, we already handled this case above
# Just ensure the values remain consistent
t_out_c = t_in_c
mdot_kg_per_s = 0
q_fluid_kw = 0
mdot_fuel_kg_per_s = 0
elif max_t_out_c is not None and t_out_c > max_t_out_c:
t_out_c = max_t_out_c
# Keep power constant and recalculate mass flow
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
else:
# If temperature difference is too small, set mass flow to zero
mdot_kg_per_s = 0
q_fluid_kw = 0
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# If allow_stop is False and power would drop below min_q_kw due to temperature constraint,
# increase mass flow to maintain minimum power
if (min_q_kw is not None and allow_stop == False and
q_fluid_kw > 1e-3 and q_fluid_kw < min_q_kw - 1e-3):
q_fluid_kw = min_q_kw
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Recalculate mass flow to achieve min power at constrained temperature
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
if min_q_kw is not None:
if 1e-3 < q_fluid_kw < min_q_kw - 1e-3:
# If the thermal power is too low but not null, apply min power constraint
q_fluid_kw = min_q_kw
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Recalculate the fluid mass flow is the temperature difference is > 0
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
else:
# If not, recalculate the output temperature instead
t_out_c = t_in_c + q_fluid_kw / (mdot_kg_per_s * cp_fluid_kj_per_kgk)
elif q_fluid_kw < 1e-3 and allow_stop == False and not np.isnan(q_previous_kw) and q_previous_kw > 1e-3:
q_fluid_kw = min_q_kw
mdot_fuel_kg_per_s = q_fluid_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Recalculate the fluid mass flow is the temperature difference is > 0
if t_out_c - t_in_c > 1e-3:
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
elif mdot_kg_per_s != 0:
# If not, recalculate the output temperature instead
t_out_c = t_in_c + q_fluid_kw / (mdot_kg_per_s * cp_fluid_kj_per_kgk)
else:
q_fluid_kw = min_q_kw
t_out_c = t_out_c + delta_t_previous_c
mdot_kg_per_s = q_fluid_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
return q_fluid_kw, mdot_kg_per_s, t_in_c, t_out_c, mdot_fuel_kg_per_s
[docs]
class GasBoilerController(BasicProsumerController):
"""
Controller for gas boilers.
:param prosumer: The prosumer object
:param gas_boiler_object: The gas boiler object
:param order: The order of the controller
:param level: The level of the controller
:param in_service: The in-service status of the controller
:param index: The index of the controller
:param kwargs: Additional keyword arguments
"""
[docs]
def name_class(self):
return "gas_boiler_controller"
def __init__(self, prosumer, gas_boiler_object, order, level, in_service=True, index=None,
name=None, **kwargs):
"""
Initializes the GasBoilerController.
"""
super().__init__(prosumer, gas_boiler_object, order=order, level=level, in_service=in_service,
index=index, name=name, **kwargs)
self.fluid = prosumer.fluid
max_q_kw = self._get_element_param(prosumer, 'max_q_kw')
min_q_kw = self._get_element_param(prosumer, 'min_q_kw')
if not np.isnan(max_q_kw) and not np.isnan(min_q_kw) and min_q_kw > max_q_kw:
raise ValueError(f"Gas Boiler {self.name} in prosumer {prosumer.name} has min_q_kw > max_q_kw ({min_q_kw} > {max_q_kw})")
def _calculate_gas_boiler(self, prosumer, mdot_kg_per_s, t_out_c, t_in_c):
"""
Main method for Gas Boiler physical calculation during one time step
:param mdot_kg_per_s: Mass flow rate in kg/s
:param t_out_c: Output provided temperature to the feed pipe in °C
:param t_in_c: Input temperature from return pipe in °C
"""
cp_fluid_kj_per_kgk = self.fluid.get_heat_capacity(CELSIUS_TO_K + (t_out_c + t_in_c) / 2) / 1000
max_q_kw = self._get_element_param(prosumer, 'max_q_kw')
if np.isnan(max_q_kw):
max_q_kw = None
min_q_kw = self._get_element_param(prosumer, 'min_q_kw')
if np.isnan(min_q_kw):
min_q_kw = None
efficiency_percent = self._get_element_param(prosumer, 'efficiency_percent')
heating_value_kj_per_kg = self._get_element_param(prosumer, 'heating_value_kj_per_kg')
max_ramp_up_kw_per_s = self._get_element_param(prosumer, 'max_ramp_up_kw_per_s')
if np.isnan(max_ramp_up_kw_per_s):
max_ramp_up_kw_per_s = None
max_ramp_down_kw_per_s = self._get_element_param(prosumer, 'max_ramp_down_kw_per_s')
if np.isnan(max_ramp_down_kw_per_s):
max_ramp_down_kw_per_s = None
q_previous_kw = self.last_result.get('q_kw', np.nan)
delta_t_previous_c = self.last_result.get('t_out_c', np.nan) - self.last_result.get('t_in_c', np.nan)
allow_stop = self._get_element_param(prosumer, 'allow_stop')
if allow_stop == None or np.isnan(allow_stop):
allow_stop = True
max_t_out_c = self._get_element_param(prosumer, 'max_t_out_c')
if np.isnan(max_t_out_c):
max_t_out_c = None
q_fluid_kw, mdot_kg_per_s, t_in_c, t_out_c, mdot_fuel_kg_per_s = _calculate_gas_boiler_temp(mdot_kg_per_s,
t_out_c,
t_in_c,
cp_fluid_kj_per_kgk,
heating_value_kj_per_kg,
efficiency_percent,
max_q_kw,
min_q_kw,
q_previous_kw,
delta_t_previous_c,
max_ramp_up_kw_per_s,
max_ramp_down_kw_per_s,
self.resol,
allow_stop,
max_t_out_c)
return q_fluid_kw, mdot_kg_per_s, t_in_c, t_out_c, mdot_fuel_kg_per_s
[docs]
def control_step(self, prosumer):
"""
Executes the control step for the controller.
:param prosumer: The prosumer object
"""
if not (self.in_service and getattr(prosumer, self.obj.element_name).iloc[self.obj.element_index[0]].in_service):
self.applied = True
return
super().control_step(prosumer)
t_out_required_c, t_in_required_c, mdot_tab_required_kg_per_s = self.t_m_to_deliver(prosumer)
mdot_required_kg_per_s = np.sum(mdot_tab_required_kg_per_s)
assert not np.isnan(t_out_required_c), f"Gas Boiler {self.name} t_out_required_c is NaN for timestep {self.time} in prosumer {prosumer.name}"
assert not np.isnan(t_in_required_c), f"Gas Boiler {self.name} t_in_required_c is NaN for timestep {self.time} in prosumer {prosumer.name}"
assert not np.isnan(mdot_required_kg_per_s).any(), f"Gas Boiler {self.name} mdot_required_kg_per_s is NaN for timestep {self.time} in prosumer {prosumer.name}"
assert t_out_required_c >= t_in_required_c, f"Gas Boiler {self.name} t_out_required_c is lower than t_in_required_c for timestep {self.time} in prosumer {prosumer.name}"
rerun = True
while rerun:
q_kw, mdot_delivered_kg_per_s, t_in_c, t_out_c, mdot_gas_kg_per_s = self._calculate_gas_boiler(
prosumer,
mdot_required_kg_per_s,
t_out_required_c,
t_in_required_c,
)
overflow_strategy = self._get_element_param(prosumer, 'overflow_strategy')
if overflow_strategy is None or (isinstance(overflow_strategy, float) and np.isnan(overflow_strategy)):
overflow_strategy = "cap"
result_mdot_tab_kg_per_s = self._merit_order_mass_flow(
prosumer,
mdot_delivered_kg_per_s,
mdot_tab_required_kg_per_s,
overflow_strategy=overflow_strategy,
)
rerun = False
if len(self._get_mapped_responders(prosumer)) > 1 and mdot_delivered_kg_per_s < mdot_required_kg_per_s:
# If the gas boiler is not able to deliver the required mass flow,
# recalculate the input temperature, considering that all the downstream elements will be
# still return the same temperature, even if the mass flow delivered to them by the Boiler is lower
t_return_tab_c = self.get_treturn_tab_c(prosumer)
if abs(mdot_delivered_kg_per_s) > 1e-8:
t_in_new_c = np.sum(result_mdot_tab_kg_per_s * t_return_tab_c) / mdot_delivered_kg_per_s
else:
t_in_new_c = t_in_required_c
if abs(t_in_new_c - t_in_required_c) > 1:
# If this recalculation changes the input temperature, rerun the calculation
# with the new temperature
t_in_required_c = t_in_new_c
rerun = True
# After merit-order capping, ensure mass and energy balance at the interface:
# use the actually delivered mass flow (sum of responder flows) and, if necessary,
# increase the outlet temperature so that the same thermal power q_kw is carried
# by this mass flow.
mdot_used_kg_per_s = np.sum(result_mdot_tab_kg_per_s)
tol = 1e-9
if abs(mdot_delivered_kg_per_s - mdot_used_kg_per_s) > tol:
cp_fluid_kj_per_kgk = self.fluid.get_heat_capacity(CELSIUS_TO_K + (t_out_c + t_in_c) / 2) / 1000
if mdot_used_kg_per_s > tol:
t_out_c = t_in_c + q_kw / (cp_fluid_kj_per_kgk * mdot_used_kg_per_s)
mdot_delivered_kg_per_s = mdot_used_kg_per_s
# Reapply max_t_out_c constraint after mass/energy balance adjustment
max_t_out_c = self._get_element_param(prosumer, 'max_t_out_c')
if not np.isnan(max_t_out_c) and t_out_c > max_t_out_c:
t_out_c = max_t_out_c
# Recalculate power to maintain consistency
q_kw = mdot_delivered_kg_per_s * cp_fluid_kj_per_kgk * (t_out_c - t_in_c)
# Recalculate fuel mass flow to maintain consistency with new power
efficiency_percent = self._get_element_param(prosumer, 'efficiency_percent')
heating_value_kj_per_kg = self._get_element_param(prosumer, 'heating_value_kj_per_kg')
mdot_gas_kg_per_s = q_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# If allow_stop is False and power dropped below min_q_kw due to temperature constraint,
# we need to increase mass flow to maintain minimum power
min_q_kw = self._get_element_param(prosumer, 'min_q_kw')
allow_stop = self._get_element_param(prosumer, 'allow_stop')
if allow_stop == None or np.isnan(allow_stop):
allow_stop = True
if (not np.isnan(min_q_kw) and allow_stop == False and
q_kw > 1e-3 and q_kw < min_q_kw - 1e-3):
# Increase mass flow to achieve min_q_kw at constrained temperature
mdot_delivered_kg_per_s = min_q_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
q_kw = min_q_kw
mdot_gas_kg_per_s = q_kw / (efficiency_percent / 100) / heating_value_kj_per_kg
# Update the result mass flows to reflect the increased delivery
if len(result_mdot_tab_kg_per_s) > 0:
result_mdot_tab_kg_per_s = np.array(result_mdot_tab_kg_per_s) * (mdot_delivered_kg_per_s / mdot_used_kg_per_s)
elif -tol < mdot_used_kg_per_s < tol and q_kw > tol:
mdot_delivered_kg_per_s = q_kw / (cp_fluid_kj_per_kgk * (t_out_c - t_in_c))
# update result_mdot_tab_kg_per_s with the new mass flow, distribute evenly if several responders
if len(result_mdot_tab_kg_per_s) > 0:
result_mdot_tab_kg_per_s = np.array(result_mdot_tab_kg_per_s) + (mdot_delivered_kg_per_s - mdot_used_kg_per_s) / len(result_mdot_tab_kg_per_s)
else:
result_mdot_tab_kg_per_s = np.array([mdot_delivered_kg_per_s])
assert q_kw >= 0, (
f"Gas Boiler {self.name} q_kw is negative ({q_kw}) for timestep {self.time} in prosumer {prosumer.name}"
)
cp_fluid_kj_per_kgk = self.fluid.get_heat_capacity(CELSIUS_TO_K + (t_out_c + t_in_c) / 2) / 1000
self._check_fluid_mix_balance(prosumer,
q_kw=q_kw,
mdot_kg_per_s=mdot_delivered_kg_per_s,
t_out_c=t_out_c,
t_in_c=t_in_c,
result_mdot_tab_kg_per_s=result_mdot_tab_kg_per_s,
cp_fluid_kj_per_kgk=cp_fluid_kj_per_kgk)
result_fluid_mix = []
for mdot_kg_per_s in result_mdot_tab_kg_per_s:
result_fluid_mix.append({FluidMixMapping.TEMPERATURE_KEY: t_out_c,
FluidMixMapping.MASS_FLOW_KEY: mdot_kg_per_s})
result = np.array([[q_kw, mdot_delivered_kg_per_s, t_in_c, t_out_c, mdot_gas_kg_per_s]])
self.last_result = {
"q_kw": q_kw,
"mdot_delivered_kg_per_s": mdot_delivered_kg_per_s,
"t_in_c": t_in_c,
"t_out_c": t_out_c,
"mdot_gas_kg_per_s": mdot_gas_kg_per_s,
}
self.finalize(prosumer, result, result_fluid_mix)
self.applied = True